✨ New Arrivals Just Dropped!Explore
SHEL LAB SRI Peltier Cooled Incubators
HomeStore

SHEL LAB SRI Peltier Cooled Incubators

SHEL LAB SRI Peltier Cooled Incubators

Select Size
From $1,681.20

Original: $5,604.00

-70%
SHEL LAB SRI Peltier Cooled Incubators

$5,604.00

$1,681.20

The Story

Overview

Innovative peltier cooling technology, eliminates the need for a refrigeration compressor in the peltier cooled series. These units use 78% less power than alternative models and reduce room air conditioning loads by 75%. They also include 75 pound capacity shelves, which eliminates sagging. These incubators meet APHA specifications for Biochemical Oxygen Demand (B.O.D.) and include a mechanical convection system to ensure even air distribution, digital temperature set controller, over temperature limit control, and a digital temperature display.

Features:

  • Microprocessor Control
  • Precise Temperature Control
  • Superior Uniformity
  • Independent Overtemperature Thermostat
  • Over Temperature Alarm
  • Temperature Uniformity +/- 0.5ºC at 20ºC
  • Temperature Range 15°C to 40°C at 20°C Ambient
  • P.I.D. Temperature_Control
  • LED Display of Setpoint and Chamber Temperature
  • High Limit Thermostat
  • Interior Electrical Outlet
  • Fan Assisted/Forced-Air Circulation
  • 24 Month Limited Warranty

PLEASE NOTE: SRI Peltier Cooled Incubators are manufactured at the time the order is placed. A three week lead time should be expected.

    Key Attributes
    Cu ft. 6.5, 19.3
    Max Temp 40°C at 20°C Ambient
    Min Temp 15°C at 20°C Ambient
    Temp Uniformity ± 0.5°C
    Interior Outlets Yes
    Alarms Yes
    Datalogging Capable No
    Warranty (years) 2
    Site Floor
    Weight (lbs) 245, 405

     

    Manufacturer Specifications   
    BOD Incubators Details SRI6P SRI20P
    Under Counter Large Capacity
    Exterior Dimensions (wxdxh) Inches 30.0 x 31.5 x 33.5 30.0 x 31.5 x 69.5
    Chamber Dimensions (wxdxh) Inches 25.5 x 24.0 x 18.5 25.5 x 24.0 x 54.5
    Incubator Chamber Capacity cu ft 6.5 19.3
    L 185 546
    Interior Outlet Number 120V -1 / 230V-2 120V-1 / 230V -2
    Bottle Capacity Number 120 300
    Number of Shelves Included 2 5
    FAQ

    Do the SRI Peltier Cooled Incubators have internal lights? What kind of lighting is used?

    Yes, there are internal lights which activate upon door opening. All Sheldon Manufacturing Peltier-cooled incubators use only low-heat LED lights.

     

    How does the electricity usage of the SRI Peltier Cooled Incubators compare to traditional compressor-cooled incubators?

    Peltier cooling is much more efficient. Peltier cooled incubators will consume significantly less electricity and produce less waste heat than traditional refrigerated incubators.

     

    How reliable is a peltier-cooled incubator? What is the expected lifespan?

    Peltier-cooled incubators generally have somewhat longer lives than traditional, compressor-cooled incubators. The mean time between failure for thermoelectric Peltier cooling plates have been estimated to have between 100,000 and 200,000 hours mean time between failures, which would equate to approximately 11.5 - 23 years of continuous use. Furthermore, the thermoelectric cooling and heating device is easier and less expensive to replace than a compressor, and does not require a refrigeration technician to do so.

    SHEL LAB SRI Peltier Cooled Incubators - Image 2

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    SHEL LAB SRI Peltier Cooled Incubators - Image 3

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    Description

    Overview

    Innovative peltier cooling technology, eliminates the need for a refrigeration compressor in the peltier cooled series. These units use 78% less power than alternative models and reduce room air conditioning loads by 75%. They also include 75 pound capacity shelves, which eliminates sagging. These incubators meet APHA specifications for Biochemical Oxygen Demand (B.O.D.) and include a mechanical convection system to ensure even air distribution, digital temperature set controller, over temperature limit control, and a digital temperature display.

    Features:

    • Microprocessor Control
    • Precise Temperature Control
    • Superior Uniformity
    • Independent Overtemperature Thermostat
    • Over Temperature Alarm
    • Temperature Uniformity +/- 0.5ºC at 20ºC
    • Temperature Range 15°C to 40°C at 20°C Ambient
    • P.I.D. Temperature_Control
    • LED Display of Setpoint and Chamber Temperature
    • High Limit Thermostat
    • Interior Electrical Outlet
    • Fan Assisted/Forced-Air Circulation
    • 24 Month Limited Warranty

    PLEASE NOTE: SRI Peltier Cooled Incubators are manufactured at the time the order is placed. A three week lead time should be expected.

      Key Attributes
      Cu ft. 6.5, 19.3
      Max Temp 40°C at 20°C Ambient
      Min Temp 15°C at 20°C Ambient
      Temp Uniformity ± 0.5°C
      Interior Outlets Yes
      Alarms Yes
      Datalogging Capable No
      Warranty (years) 2
      Site Floor
      Weight (lbs) 245, 405

       

      Manufacturer Specifications   
      BOD Incubators Details SRI6P SRI20P
      Under Counter Large Capacity
      Exterior Dimensions (wxdxh) Inches 30.0 x 31.5 x 33.5 30.0 x 31.5 x 69.5
      Chamber Dimensions (wxdxh) Inches 25.5 x 24.0 x 18.5 25.5 x 24.0 x 54.5
      Incubator Chamber Capacity cu ft 6.5 19.3
      L 185 546
      Interior Outlet Number 120V -1 / 230V-2 120V-1 / 230V -2
      Bottle Capacity Number 120 300
      Number of Shelves Included 2 5
      FAQ

      Do the SRI Peltier Cooled Incubators have internal lights? What kind of lighting is used?

      Yes, there are internal lights which activate upon door opening. All Sheldon Manufacturing Peltier-cooled incubators use only low-heat LED lights.

       

      How does the electricity usage of the SRI Peltier Cooled Incubators compare to traditional compressor-cooled incubators?

      Peltier cooling is much more efficient. Peltier cooled incubators will consume significantly less electricity and produce less waste heat than traditional refrigerated incubators.

       

      How reliable is a peltier-cooled incubator? What is the expected lifespan?

      Peltier-cooled incubators generally have somewhat longer lives than traditional, compressor-cooled incubators. The mean time between failure for thermoelectric Peltier cooling plates have been estimated to have between 100,000 and 200,000 hours mean time between failures, which would equate to approximately 11.5 - 23 years of continuous use. Furthermore, the thermoelectric cooling and heating device is easier and less expensive to replace than a compressor, and does not require a refrigeration technician to do so.