✨ New Arrivals Just Dropped!Explore
PRESTO W50 Process System
HomeStore

PRESTO W50 Process System

PRESTO W50 Process System

Select Heating Capacity
Select Certification
From $24,399.30

Original: $81,331.00

-70%
PRESTO W50 Process System

$81,331.00

$24,399.30

The Story

Overview

The rapid compensation of reactions even at higher ambient temperatures is the domain of the water-cooled W50 units. High heating and cooling capacity paired with powerful pumps. Both systems are water-cooled, the W50t offers increased heating capacity of 10 kW.

Features:

  • For highly precise, external temperature applications
  • Rapid heating and cooling
  • Wide working temperature ranges without changing fluids
  • Highest performance with small footprint
  • Space-saving design optimizes space utilization in your lab
  • 5,7” industrial color TFT touch screen
  • USB connection
  • Ethernet
  • SD-Card slot
  • RS232
  • Modbus
  • RS485 (Accessory)
  • Profibus DP (Accessory)
  • Pump pressure up to 3.2 bar, max. flow rate 76 l/min
  • Second external Pt100 sensor connection (accessory)
  • Temperature stability ±0.05 °C ... ±0.1 °C
  • Heating capacity up to 5.4 kW (or 10 kW on the W50t)
    Key Attributes 
    Type Circulating
    Incubation Yes
    Refrigeration Yes
    Temp Range (°C) -50 ... +250°C
    Capacity (L) N/A
    Circulation External Only
    Brand Julabo
    MaxFlow Rate (l/min) 76
    Temp Stability (°C) ±0.05 to 0.1°C
    Timer Yes
    Alarms Yes
    Digital or Mechanical Digital
    Data connection Yes
    Tank Material N/A
    Sample Agitation No
    Media Racks Available No
    Warranty (years) 1
    Weight (lb) 463

     

    Manufacturer Specifications
    Dimensions 20.9 x 26.2 x 49.6 in. 20.9 x 26.2 x 49.6 in.
    Filling volume expansion vessel 11.5 l 11.5 l
    Internal usable expansion volume 7.5 l 7.5 l
    Minimal process volume 7.5 l 7.5 l
    Active heat exchanger volume 3.5 l 3.5 l
    Weight 463 lbs 463 lbs
    Pump connections M30x1.5 male M30x1.5 male
    Cooling Water Connection G¾ in. G¾ in.
    Working temperature range -50.0 ... +250.0 °C -50.0 ... +250.0 °C
    Temperature stability +/-0.05 ... +/-0.1 °C +/-0.05 ... +/-0.1 °C
    Setting the resolution of the temperature display 0.01 °C 0.01 °C
    Temperature display resolution 0.01 °C 0.01 °C
    Ambient temperature +5.0 ... +40.0 °C +5.0 ... +40.0 °C

    Data based on voltage version:

    208V/3PPE/60Hz (Without Plug)

    208V/3PPE/60Hz (Without Plug)

    Heating capacity 5.5 kW 10 kW
    Cooling capacity (Medium: Ethanol) 200°C/7kW | 20°C/7.5kW | 0°C/6.5kW | -10°C/5 kW | -20°C/3kW | -30°C/1.8kW | -40°C/0.6kW 200°C/7kW | 20°C/7.5kW | 0°C/6.5kW | -10°C/5 kW | -20°C/3kW | -30°C/1.8kW | -40°C/0.6kW
    Pump capacity flow rate 35 ... 76 l/min 35 ... 76 l/min
    Pump capacity flow pressure 7 ... 43.5 psi 7 ... 43.5 psi
    Viscosity max. 50 cST 50 cST

    Refrigerant stage 1

    R507 R507
    Global Warming Potential for R507 3985 3985
    Filling volume 0 g 0 g
    Carbon dioxide equivalent 0 t 0 t
    Cooling of compressor 1-stage Water 1-stage Water
    Cooling water pressure max. 87 ... 79.8 psi 87 ... 79.8 psi
    Cooling water difference pressure 7.3 bar 7.3 bar
    Cooling water temperature max. 30 °C 30 °C
    1.0Cooling water consumption 8 ... 12 l/min 8 ... 12 l/min
    Sound pressure level 65 dbA 65 dbA
    Classification according to DIN12876-1 Classification III (FL) Classification III (FL)
    IP Code according to IEC 60529 IP 20 IP 20
    Pump type Centrifugal Pump (Magnetically coupled) Centrifugal Pump (Magnetically coupled)
    External pt100 sensor connection integrated integrated
    2nd external Pt100 sensor connection accessory accessory
    Integrated programmer 8x60 steps 8x60 steps
    Temperature control ICC ICC
    Absolute temperature calibration 3 Point Calibration 3 Point Calibration
    Temperature display 5.7" TFT Touchscreen 5.7" TFT Touchscreen
    Temperature setting Touchscreen Touchscreen
    PRESTO W50 Process System - Image 2

    Details & Craftsmanship

    Every detail has been carefully considered to bring you the perfect product.

    Description

    Overview

    The rapid compensation of reactions even at higher ambient temperatures is the domain of the water-cooled W50 units. High heating and cooling capacity paired with powerful pumps. Both systems are water-cooled, the W50t offers increased heating capacity of 10 kW.

    Features:

    • For highly precise, external temperature applications
    • Rapid heating and cooling
    • Wide working temperature ranges without changing fluids
    • Highest performance with small footprint
    • Space-saving design optimizes space utilization in your lab
    • 5,7” industrial color TFT touch screen
    • USB connection
    • Ethernet
    • SD-Card slot
    • RS232
    • Modbus
    • RS485 (Accessory)
    • Profibus DP (Accessory)
    • Pump pressure up to 3.2 bar, max. flow rate 76 l/min
    • Second external Pt100 sensor connection (accessory)
    • Temperature stability ±0.05 °C ... ±0.1 °C
    • Heating capacity up to 5.4 kW (or 10 kW on the W50t)
      Key Attributes 
      Type Circulating
      Incubation Yes
      Refrigeration Yes
      Temp Range (°C) -50 ... +250°C
      Capacity (L) N/A
      Circulation External Only
      Brand Julabo
      MaxFlow Rate (l/min) 76
      Temp Stability (°C) ±0.05 to 0.1°C
      Timer Yes
      Alarms Yes
      Digital or Mechanical Digital
      Data connection Yes
      Tank Material N/A
      Sample Agitation No
      Media Racks Available No
      Warranty (years) 1
      Weight (lb) 463

       

      Manufacturer Specifications
      Dimensions 20.9 x 26.2 x 49.6 in. 20.9 x 26.2 x 49.6 in.
      Filling volume expansion vessel 11.5 l 11.5 l
      Internal usable expansion volume 7.5 l 7.5 l
      Minimal process volume 7.5 l 7.5 l
      Active heat exchanger volume 3.5 l 3.5 l
      Weight 463 lbs 463 lbs
      Pump connections M30x1.5 male M30x1.5 male
      Cooling Water Connection G¾ in. G¾ in.
      Working temperature range -50.0 ... +250.0 °C -50.0 ... +250.0 °C
      Temperature stability +/-0.05 ... +/-0.1 °C +/-0.05 ... +/-0.1 °C
      Setting the resolution of the temperature display 0.01 °C 0.01 °C
      Temperature display resolution 0.01 °C 0.01 °C
      Ambient temperature +5.0 ... +40.0 °C +5.0 ... +40.0 °C

      Data based on voltage version:

      208V/3PPE/60Hz (Without Plug)

      208V/3PPE/60Hz (Without Plug)

      Heating capacity 5.5 kW 10 kW
      Cooling capacity (Medium: Ethanol) 200°C/7kW | 20°C/7.5kW | 0°C/6.5kW | -10°C/5 kW | -20°C/3kW | -30°C/1.8kW | -40°C/0.6kW 200°C/7kW | 20°C/7.5kW | 0°C/6.5kW | -10°C/5 kW | -20°C/3kW | -30°C/1.8kW | -40°C/0.6kW
      Pump capacity flow rate 35 ... 76 l/min 35 ... 76 l/min
      Pump capacity flow pressure 7 ... 43.5 psi 7 ... 43.5 psi
      Viscosity max. 50 cST 50 cST

      Refrigerant stage 1

      R507 R507
      Global Warming Potential for R507 3985 3985
      Filling volume 0 g 0 g
      Carbon dioxide equivalent 0 t 0 t
      Cooling of compressor 1-stage Water 1-stage Water
      Cooling water pressure max. 87 ... 79.8 psi 87 ... 79.8 psi
      Cooling water difference pressure 7.3 bar 7.3 bar
      Cooling water temperature max. 30 °C 30 °C
      1.0Cooling water consumption 8 ... 12 l/min 8 ... 12 l/min
      Sound pressure level 65 dbA 65 dbA
      Classification according to DIN12876-1 Classification III (FL) Classification III (FL)
      IP Code according to IEC 60529 IP 20 IP 20
      Pump type Centrifugal Pump (Magnetically coupled) Centrifugal Pump (Magnetically coupled)
      External pt100 sensor connection integrated integrated
      2nd external Pt100 sensor connection accessory accessory
      Integrated programmer 8x60 steps 8x60 steps
      Temperature control ICC ICC
      Absolute temperature calibration 3 Point Calibration 3 Point Calibration
      Temperature display 5.7" TFT Touchscreen 5.7" TFT Touchscreen
      Temperature setting Touchscreen Touchscreen