Original: $81,331.00
-70%$81,331.00
$24,399.30The Story
Overview
The rapid compensation of reactions even at higher ambient temperatures is the domain of the water-cooled W50 units. High heating and cooling capacity paired with powerful pumps. Both systems are water-cooled, the W50t offers increased heating capacity of 10 kW.
Features:
- For highly precise, external temperature applications
- Rapid heating and cooling
- Wide working temperature ranges without changing fluids
- Highest performance with small footprint
- Space-saving design optimizes space utilization in your lab
- 5,7” industrial color TFT touch screen
- USB connection
- Ethernet
- SD-Card slot
- RS232
- Modbus
- RS485 (Accessory)
- Profibus DP (Accessory)
- Pump pressure up to 3.2 bar, max. flow rate 76 l/min
- Second external Pt100 sensor connection (accessory)
- Temperature stability ±0.05 °C ... ±0.1 °C
- Heating capacity up to 5.4 kW (or 10 kW on the W50t)
Key Attributes
| Type | Circulating |
| Incubation | Yes |
| Refrigeration | Yes |
| Temp Range (°C) | -50 ... +250°C |
| Capacity (L) | N/A |
| Circulation | External Only |
| Brand | Julabo |
| MaxFlow Rate (l/min) | 76 |
| Temp Stability (°C) | ±0.05 to 0.1°C |
| Timer | Yes |
| Alarms | Yes |
| Digital or Mechanical | Digital |
| Data connection | Yes |
| Tank Material | N/A |
| Sample Agitation | No |
| Media Racks Available | No |
| Warranty (years) | 1 |
| Weight (lb) | 463 |
Manufacturer Specifications
| Dimensions | 20.9 x 26.2 x 49.6 in. | 20.9 x 26.2 x 49.6 in. |
| Filling volume expansion vessel | 11.5 l | 11.5 l |
| Internal usable expansion volume | 7.5 l | 7.5 l |
| Minimal process volume | 7.5 l | 7.5 l |
| Active heat exchanger volume | 3.5 l | 3.5 l |
| Weight | 463 lbs | 463 lbs |
| Pump connections | M30x1.5 male | M30x1.5 male |
| Cooling Water Connection | G¾ in. | G¾ in. |
| Working temperature range | -50.0 ... +250.0 °C | -50.0 ... +250.0 °C |
| Temperature stability | +/-0.05 ... +/-0.1 °C | +/-0.05 ... +/-0.1 °C |
| Setting the resolution of the temperature display | 0.01 °C | 0.01 °C |
| Temperature display resolution | 0.01 °C | 0.01 °C |
| Ambient temperature | +5.0 ... +40.0 °C | +5.0 ... +40.0 °C |
|
Data based on voltage version: |
208V/3PPE/60Hz (Without Plug) |
208V/3PPE/60Hz (Without Plug) |
| Heating capacity | 5.5 kW | 10 kW |
| Cooling capacity (Medium: Ethanol) | 200°C/7kW | 20°C/7.5kW | 0°C/6.5kW | -10°C/5 kW | -20°C/3kW | -30°C/1.8kW | -40°C/0.6kW | 200°C/7kW | 20°C/7.5kW | 0°C/6.5kW | -10°C/5 kW | -20°C/3kW | -30°C/1.8kW | -40°C/0.6kW |
| Pump capacity flow rate | 35 ... 76 l/min | 35 ... 76 l/min |
| Pump capacity flow pressure | 7 ... 43.5 psi | 7 ... 43.5 psi |
| Viscosity max. | 50 cST | 50 cST |
|
Refrigerant stage 1 |
R507 | R507 |
| Global Warming Potential for R507 | 3985 | 3985 |
| Filling volume | 0 g | 0 g |
| Carbon dioxide equivalent | 0 t | 0 t |
| Cooling of compressor | 1-stage Water | 1-stage Water |
| Cooling water pressure max. | 87 ... 79.8 psi | 87 ... 79.8 psi |
| Cooling water difference pressure | 7.3 bar | 7.3 bar |
| Cooling water temperature max. | 30 °C | 30 °C |
| 1.0Cooling water consumption | 8 ... 12 l/min | 8 ... 12 l/min |
| Sound pressure level | 65 dbA | 65 dbA |
| Classification according to DIN12876-1 | Classification III (FL) | Classification III (FL) |
| IP Code according to IEC 60529 | IP 20 | IP 20 |
| Pump type | Centrifugal Pump (Magnetically coupled) | Centrifugal Pump (Magnetically coupled) |
| External pt100 sensor connection | integrated | integrated |
| 2nd external Pt100 sensor connection | accessory | accessory |
| Integrated programmer | 8x60 steps | 8x60 steps |
| Temperature control | ICC | ICC |
| Absolute temperature calibration | 3 Point Calibration | 3 Point Calibration |
| Temperature display | 5.7" TFT Touchscreen | 5.7" TFT Touchscreen |
| Temperature setting | Touchscreen | Touchscreen |

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.
Description
Overview
The rapid compensation of reactions even at higher ambient temperatures is the domain of the water-cooled W50 units. High heating and cooling capacity paired with powerful pumps. Both systems are water-cooled, the W50t offers increased heating capacity of 10 kW.
Features:
- For highly precise, external temperature applications
- Rapid heating and cooling
- Wide working temperature ranges without changing fluids
- Highest performance with small footprint
- Space-saving design optimizes space utilization in your lab
- 5,7” industrial color TFT touch screen
- USB connection
- Ethernet
- SD-Card slot
- RS232
- Modbus
- RS485 (Accessory)
- Profibus DP (Accessory)
- Pump pressure up to 3.2 bar, max. flow rate 76 l/min
- Second external Pt100 sensor connection (accessory)
- Temperature stability ±0.05 °C ... ±0.1 °C
- Heating capacity up to 5.4 kW (or 10 kW on the W50t)
Key Attributes
| Type | Circulating |
| Incubation | Yes |
| Refrigeration | Yes |
| Temp Range (°C) | -50 ... +250°C |
| Capacity (L) | N/A |
| Circulation | External Only |
| Brand | Julabo |
| MaxFlow Rate (l/min) | 76 |
| Temp Stability (°C) | ±0.05 to 0.1°C |
| Timer | Yes |
| Alarms | Yes |
| Digital or Mechanical | Digital |
| Data connection | Yes |
| Tank Material | N/A |
| Sample Agitation | No |
| Media Racks Available | No |
| Warranty (years) | 1 |
| Weight (lb) | 463 |
Manufacturer Specifications
| Dimensions | 20.9 x 26.2 x 49.6 in. | 20.9 x 26.2 x 49.6 in. |
| Filling volume expansion vessel | 11.5 l | 11.5 l |
| Internal usable expansion volume | 7.5 l | 7.5 l |
| Minimal process volume | 7.5 l | 7.5 l |
| Active heat exchanger volume | 3.5 l | 3.5 l |
| Weight | 463 lbs | 463 lbs |
| Pump connections | M30x1.5 male | M30x1.5 male |
| Cooling Water Connection | G¾ in. | G¾ in. |
| Working temperature range | -50.0 ... +250.0 °C | -50.0 ... +250.0 °C |
| Temperature stability | +/-0.05 ... +/-0.1 °C | +/-0.05 ... +/-0.1 °C |
| Setting the resolution of the temperature display | 0.01 °C | 0.01 °C |
| Temperature display resolution | 0.01 °C | 0.01 °C |
| Ambient temperature | +5.0 ... +40.0 °C | +5.0 ... +40.0 °C |
|
Data based on voltage version: |
208V/3PPE/60Hz (Without Plug) |
208V/3PPE/60Hz (Without Plug) |
| Heating capacity | 5.5 kW | 10 kW |
| Cooling capacity (Medium: Ethanol) | 200°C/7kW | 20°C/7.5kW | 0°C/6.5kW | -10°C/5 kW | -20°C/3kW | -30°C/1.8kW | -40°C/0.6kW | 200°C/7kW | 20°C/7.5kW | 0°C/6.5kW | -10°C/5 kW | -20°C/3kW | -30°C/1.8kW | -40°C/0.6kW |
| Pump capacity flow rate | 35 ... 76 l/min | 35 ... 76 l/min |
| Pump capacity flow pressure | 7 ... 43.5 psi | 7 ... 43.5 psi |
| Viscosity max. | 50 cST | 50 cST |
|
Refrigerant stage 1 |
R507 | R507 |
| Global Warming Potential for R507 | 3985 | 3985 |
| Filling volume | 0 g | 0 g |
| Carbon dioxide equivalent | 0 t | 0 t |
| Cooling of compressor | 1-stage Water | 1-stage Water |
| Cooling water pressure max. | 87 ... 79.8 psi | 87 ... 79.8 psi |
| Cooling water difference pressure | 7.3 bar | 7.3 bar |
| Cooling water temperature max. | 30 °C | 30 °C |
| 1.0Cooling water consumption | 8 ... 12 l/min | 8 ... 12 l/min |
| Sound pressure level | 65 dbA | 65 dbA |
| Classification according to DIN12876-1 | Classification III (FL) | Classification III (FL) |
| IP Code according to IEC 60529 | IP 20 | IP 20 |
| Pump type | Centrifugal Pump (Magnetically coupled) | Centrifugal Pump (Magnetically coupled) |
| External pt100 sensor connection | integrated | integrated |
| 2nd external Pt100 sensor connection | accessory | accessory |
| Integrated programmer | 8x60 steps | 8x60 steps |
| Temperature control | ICC | ICC |
| Absolute temperature calibration | 3 Point Calibration | 3 Point Calibration |
| Temperature display | 5.7" TFT Touchscreen | 5.7" TFT Touchscreen |
| Temperature setting | Touchscreen | Touchscreen |