Original: $13,085.00
-70%$13,085.00
$3,925.50The Story
Overview
Incubating Heavy Duty Orbital Shakers offer exceptional temperature uniformity and are designed for a variety of shaking and incubating applications.
For Cell Cultures, Solubility Studies, Bacterial Suspensions, Extraction Procedures. Independent LED displays for temperature, speed and time. RS232. Aluminum and Cycoloy. Temperature calibration feature, overload protection, overshoot protection (temperature), load sensor, PID temperature controller, Triple Eccentric Drive system
Features:
- The exclusive Opti-Flow Forced Ventilation System utilizes twin induction or a single large fan. Air is deflected around & not directly on samples, creating a circular flow of air ensuring uniformity.
- For repeatable results, the exclusive Accu-Drive shaking system ensures speed accuracy. The Triple Eccentric Drive provides consistent shaking motion throughout the entire speed range.
- The chambers for the ISHD23HDG and ISHD23CDG units are large enough to hold 2 x 6 L Erlenmeyer flasks with optional clamps and platform.
Key Attributes
| Type | Incubated Benchtop |
| Platform Area (ft^2) | 0.99 or 2.25 |
| Platform Dimensions | 11 x 13" or 18" x 18" |
| Max Load (lb) | 35 lb or 50 lb |
| Incubation | Yes |
| Refrigeration | Only on ISHD23CDG model |
| RPM - Max | 500 |
| RPM - Min | 15 |
| Orbit Diameter (mm) | 19 mm or 25mm |
| Warranty | 2 Years |
| Weight (lb) | 79, 224, or 290 |
| Width (in) | 16" or 23.5" |
| Depth (in) | 25.5" or 32.1" |
| Height (in) | 14" or 26.6" |
Manufacturer Specifications
| Model |
ISHD16HDG | ISHD23HDG | ISHD23CDG |
| Motion | Orbital, 19 mm | Orbital, 25 mm | |
| Capacity | 35 lb (16kg)@ 75rpm, 5 lb (2.3kg)@ 500 rpm | 50 lb (22.7kg) @ 125 rpm, 10 lb (4.53kg) @ 500 rpm | |
| Temperature Range | Ambient +5°C – 65°C | 15°C below Ambient – 65°C | |
| Uniformity | ± 0.5°C at 37°C | ||
| Speed Range | 15 rpm – 500 rpm | ||
| Tray Size (LxW) | 13 in x 11 in (330 mm x 279 mm) | 18 in x 18 in (457 mm x 457 mm) | |
| Calibration | Temperature calibration | ||
| Communication | RS232 | ||
| Control | Digital | ||
| Dimensions | 16 in x 25.5 in x 14 in (406 mm x 648 mm x 356 mm) (HxLxW) | 23.5 in x 32.1 in x 26.6 in (596 mm x 815 mm x 675 mm) (HxLxW) | |
| Drive System | Triple Eccentric; Brushless DC Motor | ||
| Inner Dimensions (HxHxLxLxWxW) | 9.5 in x 241 mm x 13.4 in x 340 mm x 12 in x 305 mm | 17 in x 432 mm x 20.6 in x 523 mm x 24.8 in x 629 mm | |
| Net Weight | 79.11 lb (35.9 kg) | 224.07 lb (101.6 kg) | 290.41 lb (131.7 kg) |
| Power | 120V, 5A, 50/60Hz | 120V, 8A, 50/60Hz | 120V, 10A, 50/60Hz |
| Power Consumption | 450 W | 800 W | |
| Safety Certification | TUV | ||
| Speed Accuracy | Above 100rpm +/- 1%, Below 100rpm /- 1 rpm | ||
| Speed Range | 15 rpm – 500 rpm | ||
| Timer | 1 second – 160 hours | ||
| Tray Construction | Aluminum | ||
| Working Environment | 59°F – 90°F, 80%RH, non-condensing (15°C – 32°C, 80%RH, non-condensing) | ||

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.
Description
Overview
Incubating Heavy Duty Orbital Shakers offer exceptional temperature uniformity and are designed for a variety of shaking and incubating applications.
For Cell Cultures, Solubility Studies, Bacterial Suspensions, Extraction Procedures. Independent LED displays for temperature, speed and time. RS232. Aluminum and Cycoloy. Temperature calibration feature, overload protection, overshoot protection (temperature), load sensor, PID temperature controller, Triple Eccentric Drive system
Features:
- The exclusive Opti-Flow Forced Ventilation System utilizes twin induction or a single large fan. Air is deflected around & not directly on samples, creating a circular flow of air ensuring uniformity.
- For repeatable results, the exclusive Accu-Drive shaking system ensures speed accuracy. The Triple Eccentric Drive provides consistent shaking motion throughout the entire speed range.
- The chambers for the ISHD23HDG and ISHD23CDG units are large enough to hold 2 x 6 L Erlenmeyer flasks with optional clamps and platform.
Key Attributes
| Type | Incubated Benchtop |
| Platform Area (ft^2) | 0.99 or 2.25 |
| Platform Dimensions | 11 x 13" or 18" x 18" |
| Max Load (lb) | 35 lb or 50 lb |
| Incubation | Yes |
| Refrigeration | Only on ISHD23CDG model |
| RPM - Max | 500 |
| RPM - Min | 15 |
| Orbit Diameter (mm) | 19 mm or 25mm |
| Warranty | 2 Years |
| Weight (lb) | 79, 224, or 290 |
| Width (in) | 16" or 23.5" |
| Depth (in) | 25.5" or 32.1" |
| Height (in) | 14" or 26.6" |
Manufacturer Specifications
| Model |
ISHD16HDG | ISHD23HDG | ISHD23CDG |
| Motion | Orbital, 19 mm | Orbital, 25 mm | |
| Capacity | 35 lb (16kg)@ 75rpm, 5 lb (2.3kg)@ 500 rpm | 50 lb (22.7kg) @ 125 rpm, 10 lb (4.53kg) @ 500 rpm | |
| Temperature Range | Ambient +5°C – 65°C | 15°C below Ambient – 65°C | |
| Uniformity | ± 0.5°C at 37°C | ||
| Speed Range | 15 rpm – 500 rpm | ||
| Tray Size (LxW) | 13 in x 11 in (330 mm x 279 mm) | 18 in x 18 in (457 mm x 457 mm) | |
| Calibration | Temperature calibration | ||
| Communication | RS232 | ||
| Control | Digital | ||
| Dimensions | 16 in x 25.5 in x 14 in (406 mm x 648 mm x 356 mm) (HxLxW) | 23.5 in x 32.1 in x 26.6 in (596 mm x 815 mm x 675 mm) (HxLxW) | |
| Drive System | Triple Eccentric; Brushless DC Motor | ||
| Inner Dimensions (HxHxLxLxWxW) | 9.5 in x 241 mm x 13.4 in x 340 mm x 12 in x 305 mm | 17 in x 432 mm x 20.6 in x 523 mm x 24.8 in x 629 mm | |
| Net Weight | 79.11 lb (35.9 kg) | 224.07 lb (101.6 kg) | 290.41 lb (131.7 kg) |
| Power | 120V, 5A, 50/60Hz | 120V, 8A, 50/60Hz | 120V, 10A, 50/60Hz |
| Power Consumption | 450 W | 800 W | |
| Safety Certification | TUV | ||
| Speed Accuracy | Above 100rpm +/- 1%, Below 100rpm /- 1 rpm | ||
| Speed Range | 15 rpm – 500 rpm | ||
| Timer | 1 second – 160 hours | ||
| Tray Construction | Aluminum | ||
| Working Environment | 59°F – 90°F, 80%RH, non-condensing (15°C – 32°C, 80%RH, non-condensing) | ||

























