Original: $2,786.00
-70%$2,786.00
$835.80The Story
Overview
The models in the IKA Oven 125 dry series are powerful drying cabinets for temperature regulation, drying, ageing and heating tasks. Rapid heating and exact temperature regulation guarantee reproducible results in industrial laboratories, schools and universities, research, quality control or science. Up to 6 insertable shelves can be accommodated in the interior made of stainless steel. Aeration takes place over an electronically adjustable ventilation flap. A temperature limiter, designed according to DIN 12880 (Class 1), ensures safety. The drying cabinets can be controlled via a USB interface, and the test parameters can be displayed using software
Features:
- Oven 125 basic dry
- The IKA Oven 125 basic with its natural air exchange is ideal for temperature applications up to 250 °C. The temperature setting takes place precisely in steps of 0.1 K. To protect your samples, the maximum target temperature can be limited using a tool.
- LED Display - The modern, clearly arranged and generous display is also easy to read from a distance.
- Timer - From 1 minute up to 100 days: timer of the Oven 125 basic dry guarantees scheduled and precise procedures.
- Alarm - If the temperature drops, triggered by an open door for example, acoustic and visual warning signals are given
- Oven 125 control dry
- The Oven 125 control dry recirculating air drying cabinet heats up to 300 °C. The additional temperature selection limited TWB (DIN 12880) meets the highest security requirements. Furthermore, the temperature curve can be monitored during testing independently of the safety temperature. This means that your test material is always protected.
- A well thought out interior - The generously dimensioned interior of the Oven control dry is comfortably illuminated. A practical cable bushing at the rear of the device is provided as standard for measurements in the oven or in
- the test material. The fan switches off automatically if the door is open.
- Interfaces - The Oven control dry offers an interface for an additional sensor for direct temperature regulation in the test material. Test parameters can be stored directly on a USB stick.
- 2 Displays - All important process parameters are displayed clearly on two large TFT displays. The temperature profiles and individual user profiles can be entered via the intuitive user interface. The real-time clock enables convenient digital documentation and a time-delayed start
- Oven 125 basic /control dry glass
- A glass door is available as an option for both the IKA Oven 125 basic and control for better monitoring of your samples
Key Attributes
|
Max Temperature |
250 or 300°C |
|
Max Capacity |
4.4 cu ft |
|
Air Movement |
Natural |
|
Electrical |
220 - 240 / 115 / 100 V |
| Warranty | 2 years |
Manufacturer Specifications
| Model | BASIC (DRY / DRY GLASS) | CONTROL (DRY / DRY GLASS) |
| Heat output | 2400 W | 2400 W |
| Working temperature | room temp. +5 - 250 °C | room temp. +5 - 300 °C |
| Adjustment and display resolution | 0.1 K | 50 - 320 °C |
| Adjustment and display resolution | N/A | 0.1 K |
| Temperature stability (150°C, center, standard door) | 0.5 ±K | 0.5 ±K |
| Temperature display | yes | yes |
| Timer | yes | yes |
| Timer display | 7 segment LED | LCD |
| Time setting range | 1 - 144000 min | 1 - 142560 min |
| Number of trays max. | 6 | 6 |
| Load for one tray max. | 30 kg | 30 kg |
| Operating area inner chamber | 550 x 525 x 450 mm | 550 x 525 x 450 mm |
| Total volume inner chamber | 125 l | 125 l |
| Air outlet port diameter inside | 48 mm | 48 mm |
| Dimensions (W x H x D) | 700 x 825 x 650 mm | 700 x 825 x 650 mm |
| Weight | 74 kg | 82 kg |
| Permissible ambient temperature | 5 - 40 °C | 5 - 40 °C |
| Permissible relative humidity | 80% | 80% |
| Protection class according to DIN EN 60529 | IP 20 | IP 20 |
| RS 232 interface | N/A | yes |
| USB interface | yes | yes |
| Voltage | 220 - 240 / 115 / 100 V | 220 - 240 / 115 / 100 V |
| Frequency | 50/60 Hz | 50/60 Hz |
| Power input | 2450 W | 2500 W |
| Power input standby | 2 W | 2 W |

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.
Description
Overview
The models in the IKA Oven 125 dry series are powerful drying cabinets for temperature regulation, drying, ageing and heating tasks. Rapid heating and exact temperature regulation guarantee reproducible results in industrial laboratories, schools and universities, research, quality control or science. Up to 6 insertable shelves can be accommodated in the interior made of stainless steel. Aeration takes place over an electronically adjustable ventilation flap. A temperature limiter, designed according to DIN 12880 (Class 1), ensures safety. The drying cabinets can be controlled via a USB interface, and the test parameters can be displayed using software
Features:
- Oven 125 basic dry
- The IKA Oven 125 basic with its natural air exchange is ideal for temperature applications up to 250 °C. The temperature setting takes place precisely in steps of 0.1 K. To protect your samples, the maximum target temperature can be limited using a tool.
- LED Display - The modern, clearly arranged and generous display is also easy to read from a distance.
- Timer - From 1 minute up to 100 days: timer of the Oven 125 basic dry guarantees scheduled and precise procedures.
- Alarm - If the temperature drops, triggered by an open door for example, acoustic and visual warning signals are given
- Oven 125 control dry
- The Oven 125 control dry recirculating air drying cabinet heats up to 300 °C. The additional temperature selection limited TWB (DIN 12880) meets the highest security requirements. Furthermore, the temperature curve can be monitored during testing independently of the safety temperature. This means that your test material is always protected.
- A well thought out interior - The generously dimensioned interior of the Oven control dry is comfortably illuminated. A practical cable bushing at the rear of the device is provided as standard for measurements in the oven or in
- the test material. The fan switches off automatically if the door is open.
- Interfaces - The Oven control dry offers an interface for an additional sensor for direct temperature regulation in the test material. Test parameters can be stored directly on a USB stick.
- 2 Displays - All important process parameters are displayed clearly on two large TFT displays. The temperature profiles and individual user profiles can be entered via the intuitive user interface. The real-time clock enables convenient digital documentation and a time-delayed start
- Oven 125 basic /control dry glass
- A glass door is available as an option for both the IKA Oven 125 basic and control for better monitoring of your samples
Key Attributes
|
Max Temperature |
250 or 300°C |
|
Max Capacity |
4.4 cu ft |
|
Air Movement |
Natural |
|
Electrical |
220 - 240 / 115 / 100 V |
| Warranty | 2 years |
Manufacturer Specifications
| Model | BASIC (DRY / DRY GLASS) | CONTROL (DRY / DRY GLASS) |
| Heat output | 2400 W | 2400 W |
| Working temperature | room temp. +5 - 250 °C | room temp. +5 - 300 °C |
| Adjustment and display resolution | 0.1 K | 50 - 320 °C |
| Adjustment and display resolution | N/A | 0.1 K |
| Temperature stability (150°C, center, standard door) | 0.5 ±K | 0.5 ±K |
| Temperature display | yes | yes |
| Timer | yes | yes |
| Timer display | 7 segment LED | LCD |
| Time setting range | 1 - 144000 min | 1 - 142560 min |
| Number of trays max. | 6 | 6 |
| Load for one tray max. | 30 kg | 30 kg |
| Operating area inner chamber | 550 x 525 x 450 mm | 550 x 525 x 450 mm |
| Total volume inner chamber | 125 l | 125 l |
| Air outlet port diameter inside | 48 mm | 48 mm |
| Dimensions (W x H x D) | 700 x 825 x 650 mm | 700 x 825 x 650 mm |
| Weight | 74 kg | 82 kg |
| Permissible ambient temperature | 5 - 40 °C | 5 - 40 °C |
| Permissible relative humidity | 80% | 80% |
| Protection class according to DIN EN 60529 | IP 20 | IP 20 |
| RS 232 interface | N/A | yes |
| USB interface | yes | yes |
| Voltage | 220 - 240 / 115 / 100 V | 220 - 240 / 115 / 100 V |
| Frequency | 50/60 Hz | 50/60 Hz |
| Power input | 2450 W | 2500 W |
| Power input standby | 2 W | 2 W |