The Story
Overview
Specially designed for optimal temperature control as well as minimal sample contamination caused by external air intrusion. Models: IL-15A/25A
Features:
- Temperature range from 4°C to 70°C.
- Microprocessor PID control.
- Three point temperature calibration / Automatic tuning.
- Natural convection within the chamber induced by the heater and the fan located inside the air jacket.
- Large chamber volume: maximum 254L.
- Bright VFD display (0.1℃resolution)
- Dual delayed on/off timer modes. (1 min. to 99 hr. 59 min.)with heating level indication and quick adjustable dial knob.
- Convenient preset function for 3 most commonly used temperature settings.
- Built-in electrical outlet with a safety cover inside the chamber.
- Convenient sample monitoring without affecting chamber temperature via the inner tempered-glass door.
- Rounded inner chamber corners for easy cleaning and optimal airflow.
- Quick-release front grill for easy cleaning of the condenser.
- Built-in RS-232 port and USB port for external control and data collection.
- Automatic run after power interruption.
- Over-current protection.
- Triple independent temperature monitor system.
- Temperature deviation alarm (High/Low)
- Electronic temperature limiter (High/Low)
- Mechanical over-temperature limiter (High)
- Keypad lock function prevents accidental changes during operation.
- Audible and visible open door alarms.
Key Attributes
| Cu ft. | 5.5, 8.97 |
| Max Temp | 70°C |
| Min Temp | 4°C |
| Temp Uniformity | ± 0.2°C |
| Interior Outlets | Yes |
| Alarms | Yes |
| Datalogging Capable | Yes |
| Warranty (years) | 1 (2 years after submission of warranty registration card) |
| Site | Floor |
| Weight (lbs) | 238, 320 |
Manufacturer Specifications
| Model | IL-15A | IL-25A | |||
|---|---|---|---|---|---|
| Chamber volume (L / cu ft) | 156 / 5.5 | 254 / 8.97 | |||
| Refrigerator (Hp) | 1 / 6 HBP | 1 / 6 HBP | |||
| Temperature | Range (℃ / ℉) | 4 to 70 / +39.2 to 158 | |||
| Fluctuation 1) at 37℃ (±℃ / ℉) | 0.2 / 0.36 | ||||
| Variation 1) at 37℃ (±℃ / ℉) | 0.7 / 1.26 | ||||
| Dimension(W×D×H) | Interior (mm / inch) | 600×520×500/ 24×20.5×20 | 500×540×940/ 20×21.3×37 | ||
| Exterior (mm / inch) | 770×790×1115/ 30×31.1×43.9 | 670×805×1668/ 26.4×31.7×65.7 | |||
| No. of wire shelf (standard / max.) | 2 / 11 | 3 / 25 | |||
| Net weight (Kg / lbs) | 108 / 238.1 | 145 / 319.7 | |||
| Electrical requirements (120V) | 60Hz, 10.2A | 60Hz, 12.3A | |||
FAQ
Do the IL Air-jacketed Low Temperature Incubators have an access port?
No, they do not.
Are the IL series incubators UL listed or have a similar certification?
No, they do not. They are CE certified, but do not have an equivalent North American certification.
Description
Overview
Specially designed for optimal temperature control as well as minimal sample contamination caused by external air intrusion. Models: IL-15A/25A
Features:
- Temperature range from 4°C to 70°C.
- Microprocessor PID control.
- Three point temperature calibration / Automatic tuning.
- Natural convection within the chamber induced by the heater and the fan located inside the air jacket.
- Large chamber volume: maximum 254L.
- Bright VFD display (0.1℃resolution)
- Dual delayed on/off timer modes. (1 min. to 99 hr. 59 min.)with heating level indication and quick adjustable dial knob.
- Convenient preset function for 3 most commonly used temperature settings.
- Built-in electrical outlet with a safety cover inside the chamber.
- Convenient sample monitoring without affecting chamber temperature via the inner tempered-glass door.
- Rounded inner chamber corners for easy cleaning and optimal airflow.
- Quick-release front grill for easy cleaning of the condenser.
- Built-in RS-232 port and USB port for external control and data collection.
- Automatic run after power interruption.
- Over-current protection.
- Triple independent temperature monitor system.
- Temperature deviation alarm (High/Low)
- Electronic temperature limiter (High/Low)
- Mechanical over-temperature limiter (High)
- Keypad lock function prevents accidental changes during operation.
- Audible and visible open door alarms.
Key Attributes
| Cu ft. | 5.5, 8.97 |
| Max Temp | 70°C |
| Min Temp | 4°C |
| Temp Uniformity | ± 0.2°C |
| Interior Outlets | Yes |
| Alarms | Yes |
| Datalogging Capable | Yes |
| Warranty (years) | 1 (2 years after submission of warranty registration card) |
| Site | Floor |
| Weight (lbs) | 238, 320 |
Manufacturer Specifications
| Model | IL-15A | IL-25A | |||
|---|---|---|---|---|---|
| Chamber volume (L / cu ft) | 156 / 5.5 | 254 / 8.97 | |||
| Refrigerator (Hp) | 1 / 6 HBP | 1 / 6 HBP | |||
| Temperature | Range (℃ / ℉) | 4 to 70 / +39.2 to 158 | |||
| Fluctuation 1) at 37℃ (±℃ / ℉) | 0.2 / 0.36 | ||||
| Variation 1) at 37℃ (±℃ / ℉) | 0.7 / 1.26 | ||||
| Dimension(W×D×H) | Interior (mm / inch) | 600×520×500/ 24×20.5×20 | 500×540×940/ 20×21.3×37 | ||
| Exterior (mm / inch) | 770×790×1115/ 30×31.1×43.9 | 670×805×1668/ 26.4×31.7×65.7 | |||
| No. of wire shelf (standard / max.) | 2 / 11 | 3 / 25 | |||
| Net weight (Kg / lbs) | 108 / 238.1 | 145 / 319.7 | |||
| Electrical requirements (120V) | 60Hz, 10.2A | 60Hz, 12.3A | |||