Original: $7,340.00
-70%$7,340.00
$2,202.00The Story
Overview
The Ai RapidChill series -86°C ultra-low upright ULT freezers is designed for fast cooling, ultra-low power consumption, very low noise, and ease of maintenance. All RapidChill ultra-low freezers are UL certified.
Features
- CDC and VFC compliant, great for storage of Covid-19 vaccines, DNA, RNA, virus samples, organs, and serum
- State-of-the-art Vacuum Insulated Panel (VIP, Micro-Cellular Polyurethane) insulated
- Safe, environmentally friendly, energy efficient, and easy-to-acquire HC refrigeration system
- Remote alarm, RS-485 and optional 4-20mA transmitter
- Door lock, high or low temperature alarms, power failure alarm, door open alarm, filter clogging alarm, password protection, tons of security features to protect you, your products, and the unit
- Digital temperature display with microprocessor-based temperature controller
- All stainless steel interior for clean operation, durability, and ease of maintenance
- Dual silicon sealing gaskets for ultra airtight operation
- 48-hour battery backup for controller and alarm
- Extremely quiet and reliable
- Built-in swivel casters with leveling feet
- Compliant to UL 61010-1 and CSA C22.2 standards
Please note: This unit is NOT designed to be used on a mobile platform. The remote transmitting option requires an additional 2 week lead time.
Key Attributes
| Min. Temperature | -40°C to -86°C |
| Cubic Feet | 3.5 |
| Alarms | Yes |
| Controls | Digital |
| Defrost | Manual |
| Electrical | 115V, 60 Hz |
| Warranty(years) | 2-year full service, 3-year parts, 5-year compressor |
| Weight (lb) | 240 |
| Width (in) | 30 |
| Depth (in) | 26 |
| Height (in) | 32 |
Manufacturer Specifications
| Model | G04h |
| Electrical requirements | 110V (+/-10%) 60Hz 1-Phase 680W 6A |
| Power consumption | 5.5 kW/day |
| Performance | Temperature range: -40°C to -86°C Time from ambient to -86°C: 4 hours Uniformity: ±4°C Time from -86°C to -50°C with door close (ambient 25°C): 2 hours |
| Controller | - Style: microcomputer controlled with analog display -Range -40°C to -86°C - Step: 1°C - Thermo sensor: PT100 - Displays: internal temperature, ambient temperature, input voltage, error code - Indicators: Locked, running, power, alarm, door open, over temperature battery low, condenser clean |
| Compressor | Make: SECOP(formerly known as Danfoss), Germany Style: direct cooling Power: 115V 60Hz 1-PHASE, 0.54HP Number of compressors: one HC refrigerants: R600A, R1150 and R50 |
| Chamber | Dimensions: 13 x 19.5 x 24.5" (WxDxH) Material: powder coated steel Effective capacity: 3.5 Cu Ft Insulation: VIP (Vacuum Insulated Panel) |
| Shelf | Come with unit: oneadjustableshelf (2 compartments) Material: 304 stainless steel |
| Door and gasket | Inner door: two, stainless steel External door: one,with four layers of silicone sealing gaskets, lock-able |
| Access port | One |
| Noise level | 46 dBA |
| Communication | Standard: RS-485, USB (stores 15 years of data for compliance purpose) Optional: 4-20mA transmitter |
| Working environment | - Temperature: 10°C to 32°C (humidity <57% Rh required at 32°C) - Humidity: <80% Rh - Altitude: < 2000 m / 6561 Ft - Stable, well-ventilated platform with no excessive dust - Keep freezer at least 12 inches from any walls or ceiling - Use dedicated power, do not share outlet - Extension power cable should be less than 10 feet is required - Freezer and power outlet should be grounded properly - Avoid direct sunlight, water spill and do NOT use freezer outdoor - Clean condenser fins and remove frost inside chamber at least once a month - Important! Do not plug in your unit. Leave your Ai refrigerator or freezer for 24 hours before turning the unit on for the first time. |
| Battery backup system | 48 hours (for controller display and alarms only) |
| Unit/shipping weight & dimensions | 240 Lbs / 300 Lbs 30 x 26 x 32" / 33 x 29 x 35" (WxDxH) |
| Safety | Compressor over-temp protection Ambient over-temp protection Compressor power surge delay protection Password protection Sensor failure protection Over-temperature and low-temperature protection Power failure protection Low battery, door open, condenser clogging, system failure alarms External door with lock Ground protection |
| Compliance | UL 61010-1 CSA C22.2 |
| Warranty | 2-year full service, 3-year parts, 5-year compressor |

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.

Details & Craftsmanship
Every detail has been carefully considered to bring you the perfect product.
Description
Overview
The Ai RapidChill series -86°C ultra-low upright ULT freezers is designed for fast cooling, ultra-low power consumption, very low noise, and ease of maintenance. All RapidChill ultra-low freezers are UL certified.
Features
- CDC and VFC compliant, great for storage of Covid-19 vaccines, DNA, RNA, virus samples, organs, and serum
- State-of-the-art Vacuum Insulated Panel (VIP, Micro-Cellular Polyurethane) insulated
- Safe, environmentally friendly, energy efficient, and easy-to-acquire HC refrigeration system
- Remote alarm, RS-485 and optional 4-20mA transmitter
- Door lock, high or low temperature alarms, power failure alarm, door open alarm, filter clogging alarm, password protection, tons of security features to protect you, your products, and the unit
- Digital temperature display with microprocessor-based temperature controller
- All stainless steel interior for clean operation, durability, and ease of maintenance
- Dual silicon sealing gaskets for ultra airtight operation
- 48-hour battery backup for controller and alarm
- Extremely quiet and reliable
- Built-in swivel casters with leveling feet
- Compliant to UL 61010-1 and CSA C22.2 standards
Please note: This unit is NOT designed to be used on a mobile platform. The remote transmitting option requires an additional 2 week lead time.
Key Attributes
| Min. Temperature | -40°C to -86°C |
| Cubic Feet | 3.5 |
| Alarms | Yes |
| Controls | Digital |
| Defrost | Manual |
| Electrical | 115V, 60 Hz |
| Warranty(years) | 2-year full service, 3-year parts, 5-year compressor |
| Weight (lb) | 240 |
| Width (in) | 30 |
| Depth (in) | 26 |
| Height (in) | 32 |
Manufacturer Specifications
| Model | G04h |
| Electrical requirements | 110V (+/-10%) 60Hz 1-Phase 680W 6A |
| Power consumption | 5.5 kW/day |
| Performance | Temperature range: -40°C to -86°C Time from ambient to -86°C: 4 hours Uniformity: ±4°C Time from -86°C to -50°C with door close (ambient 25°C): 2 hours |
| Controller | - Style: microcomputer controlled with analog display -Range -40°C to -86°C - Step: 1°C - Thermo sensor: PT100 - Displays: internal temperature, ambient temperature, input voltage, error code - Indicators: Locked, running, power, alarm, door open, over temperature battery low, condenser clean |
| Compressor | Make: SECOP(formerly known as Danfoss), Germany Style: direct cooling Power: 115V 60Hz 1-PHASE, 0.54HP Number of compressors: one HC refrigerants: R600A, R1150 and R50 |
| Chamber | Dimensions: 13 x 19.5 x 24.5" (WxDxH) Material: powder coated steel Effective capacity: 3.5 Cu Ft Insulation: VIP (Vacuum Insulated Panel) |
| Shelf | Come with unit: oneadjustableshelf (2 compartments) Material: 304 stainless steel |
| Door and gasket | Inner door: two, stainless steel External door: one,with four layers of silicone sealing gaskets, lock-able |
| Access port | One |
| Noise level | 46 dBA |
| Communication | Standard: RS-485, USB (stores 15 years of data for compliance purpose) Optional: 4-20mA transmitter |
| Working environment | - Temperature: 10°C to 32°C (humidity <57% Rh required at 32°C) - Humidity: <80% Rh - Altitude: < 2000 m / 6561 Ft - Stable, well-ventilated platform with no excessive dust - Keep freezer at least 12 inches from any walls or ceiling - Use dedicated power, do not share outlet - Extension power cable should be less than 10 feet is required - Freezer and power outlet should be grounded properly - Avoid direct sunlight, water spill and do NOT use freezer outdoor - Clean condenser fins and remove frost inside chamber at least once a month - Important! Do not plug in your unit. Leave your Ai refrigerator or freezer for 24 hours before turning the unit on for the first time. |
| Battery backup system | 48 hours (for controller display and alarms only) |
| Unit/shipping weight & dimensions | 240 Lbs / 300 Lbs 30 x 26 x 32" / 33 x 29 x 35" (WxDxH) |
| Safety | Compressor over-temp protection Ambient over-temp protection Compressor power surge delay protection Password protection Sensor failure protection Over-temperature and low-temperature protection Power failure protection Low battery, door open, condenser clogging, system failure alarms External door with lock Ground protection |
| Compliance | UL 61010-1 CSA C22.2 |
| Warranty | 2-year full service, 3-year parts, 5-year compressor |