Original: $400.00
-70%$400.00
$120.00The Story
Microtip probes are designed to process samples contained in small diameter vessels at extremely high intensity. There are two configurations:
Tapered Microtips are recommended for processing yeast, spores, fungi, muscle, connective tissue, and similar samples. They screw into 1/2" horns with tapped ends.
| Tip Diameter: | 1/8" (3 mm) | 3/16" (5 mm) | 1/4" (6.5 mm) |
| Intensity: | 116 - 494 | 59.5 - 302 | 59.5 - 247 |
| Amplitude (µm): | Ultra High | Very High | High |
| Sample Volume: | 0.25 - 10 ml | 5 - 20 ml | 10 - 50 ml |
Double Stepped Microtips are recommended for processing cells with have a relatively low resistance to breakage, such as HeLa cells, blood cells, and cells in most tissue cultures. They consist of a coupler and a stepped tip and screw directly into the converter (they do not require a separate horn). They have a lower amplitude than the tapered tip but are capable of reaching into small diameter vessels of greater depth and can process volumes as small as 0.1 ml.
| Tip Diameter: | 1/8" (3 mm) |
| Intensity: | Very High |
| Amplitude (µm): | 64 - 247 |
| Sample Volume: | 0.1 - 10 ml |
PLEASE NOTE: Do not operate microtips at a setting higher than 7 on any Sonifier® model. Do not operate in air. Either may cause damage or breakage to an ultrasonic microtip.
Description
Microtip probes are designed to process samples contained in small diameter vessels at extremely high intensity. There are two configurations:
Tapered Microtips are recommended for processing yeast, spores, fungi, muscle, connective tissue, and similar samples. They screw into 1/2" horns with tapped ends.
| Tip Diameter: | 1/8" (3 mm) | 3/16" (5 mm) | 1/4" (6.5 mm) |
| Intensity: | 116 - 494 | 59.5 - 302 | 59.5 - 247 |
| Amplitude (µm): | Ultra High | Very High | High |
| Sample Volume: | 0.25 - 10 ml | 5 - 20 ml | 10 - 50 ml |
Double Stepped Microtips are recommended for processing cells with have a relatively low resistance to breakage, such as HeLa cells, blood cells, and cells in most tissue cultures. They consist of a coupler and a stepped tip and screw directly into the converter (they do not require a separate horn). They have a lower amplitude than the tapered tip but are capable of reaching into small diameter vessels of greater depth and can process volumes as small as 0.1 ml.
| Tip Diameter: | 1/8" (3 mm) |
| Intensity: | Very High |
| Amplitude (µm): | 64 - 247 |
| Sample Volume: | 0.1 - 10 ml |
PLEASE NOTE: Do not operate microtips at a setting higher than 7 on any Sonifier® model. Do not operate in air. Either may cause damage or breakage to an ultrasonic microtip.